CT1502, continued
SlUGLE STAGE HEAT PUMP
{WiTHOUT AUXILIARY HEAT) SYSTEM
IFCOMPRESSOR IS CONNECTED TO OLD THERMOSTAT'S
■y TERMINAL WITH A JUMPER TO "W. USE NEW THERMOSTAT'S
-P" ^RMINAL FOR COMPRESSOR. IF OLD THERMOSTAT HAS
ONE WIRE TO -V" ANO ONE TO "W", USb 'V AND "W" ON NEW
THERMOSTAT: DO NOT USE "P". IMPORTANT- IF OLD
THERMOSTAT US£ S A W2 ÌAU XIUAPV O ft EM£ RG E NCV HEATj
TERMINAL, THIS THERMOSTAT MAY NOT BE USED THIS
THERMOSTAT fS NOT DESIGNED TO CONTROL AUXI LIARV HEAT.
SOME HEAT PUMPS USE "S'INSTEAD OF "0"
Connect the wires to matching terminals on
the subbase. Firmly tighten screws,
Push excess wire back into wall, and plug
hole in wall with nonflammable insulation to
prevent drafts from attecting thermostat operation.
For CT1503 750-millivolt heating
Connect either wire to R terminal and the
other wire to W terminal. Firmly tighten
screws.
Push excess wire back into wall, and plug
hole in wall with nonilammable insulation to
prevent drafts from affecting thermostat operation.
69-0273—9