Honeywell T841A1316 Manuale Utente

Navigare online o scaricare Manuale Utente per Termostati Honeywell T841A1316. Honeywell T841A1316 User's Manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 6
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
MOUNTING
HOLES (4)
WIRING TERMINAL
(UP TO 12)
M2960A
BACK OF DEVICE
80
70
60
50
EM. HEAT HEAT OFF COOL
80
70
60
50
AUTO ON
FAN
EM. HEAT AUX. HEAT
CHECK
FRONT OF DEVICE
FAN SWITCH
SYSTEM SWITCH
COVER
THERMOMETER
SET POINT
SCALE
LED (UP
TO THREE)
T841A Heating-Cooling
Heat Pump Thermostat
X-XX UL
INSTALLATION INSTRUCTIONS
®U.S. Registered Trademark
Copyright © 1997 Honeywell Inc. • • All Rights Reserved
APPLICATION
The T841A Heating-Cooling TRADELINE® Thermostat
provides 24 Vac control of two-stage heating and one-
stage cooling in heat pump systems, using manual
changeover. This thermostat provides SYSTEM switch
selections of EM. HEAT-HEAT-OFF-COOL and FAN
switch selections of AUTO-ON. See Fig. 1. See Table 1 for
T841A TRADELINE® specifications.
Test holes are provided on the front of the thermostat to
accommodate test meter probes without removing the
thermostat from the wall. Remove the cover of the
thermostat to expose the test holes, which are labeled to
correspond with the terminals on the back of the
thermostat.
Table 1. T841A TRADELINE® Specifications.
Fig. 1. External view of T841A.
a
EM. HEAT LED also indicates compressor malfunction.
b
Premier White® color.
c
Sold only in Australia: degrees C.
d
CHECK LED indicates compressor malfunction.
OS Number
LED
Indication Changeover
Heat
Anticipation
Terminal
Designations Remarks
System
Switch
Auto Fan
in EM.
HEAT
T841A1308 EM. HEAT
a
,
AUX. HEAT
Manual Cool
or Heat
Stage 2 fixed,
0 to 1.5A
G, R, W
2
, E,
L, B, X, Y, O
Use when E
and W
2
are
jumpered.
EM. HEAT,
HEAT, OFF,
COOL
No
T841A1316 G, R, E, L, X
W
2
, B, W1,
Y
1
, O
Does not
replace
T841A1068.
Yes
T841A1423
b
EM. HEAT,
AUX. HEAT,
CHECK
d
Stage 2
adjustable, 0.1
to 1.2A
W
3
, G, R, W
2
,
E, L, B, X, Y,
O
Not for systems
with E to W
2
jumper
T841A1464
b,c
T841A1498 EM. HEAT Stage 2 fixed,
0 to 1.5A
G, R, W, H, B,
X, O, Y
Exact
replacement for
York model no.
2TH11703324
T841A1506
b
69-0452-8
Vedere la pagina 0
1 2 3 4 5 6

Sommario

Pagina 1 - Heat Pump Thermostat

MOUNTINGHOLES (4)WIRING TERMINAL(UP TO 12)M2960ABACK OF DEVICE80706050EM. HEAT HEAT OFF COOL 80706050AUTO ONFANEM. HEAT AUX. HEAT CHECKFR

Pagina 2 - RECYCLING NOTICE

69-0452—82T841A HEATING-COOLING HEAT PUMP THERMOSTATOPERATIONThe stages of heat make sequentially as the temperaturedrops. Make refers to the mercury

Pagina 3 - SETTINGS

69-0452—83T841A HEATING-COOLING HEAT PUMP THERMOSTATODT 1EHR 1RTD 2RTD 1ODT 2RTD 3ERH 2RDGSYSTEMSWITCHEM. HEATHEATOFFCOOLH2FALLH1C1FALLH1 & C1ANTI

Pagina 4 - 69-0452—8

69-0452—84T841A HEATING-COOLING HEAT PUMP THERMOSTATFig. 3. Internal schematic and typical wiring diagram for SUPER TRADELINE® T841A1316 with AUX. HEA

Pagina 5 - EM.HEAT HEAT OFF COOL

69-0452—85T841A HEATING-COOLING HEAT PUMP THERMOSTATFig. 5. Internal schematic and typical wiring diagram for TRADELINE® T841A1423 and T841A1464 (sold

Pagina 6 - CHECKOUT

69-0452—86T841A HEATING-COOLING HEAT PUMP THERMOSTATCHECKOUTHeatingMove the SYSTEM switch on the thermostat to HEAT andthe FAN switch to AUTO. Move th